Disinfection
12 November 2026
6 min read
Ozone vs. traditional disinfection: where each works best.
Ozone is a strong oxidant that leaves no chemical residue. That makes
it attractive for water, air and surface treatment — but it also means
the dose, contact time and off-gas have to be engineered.
Here is how we decide where ozone fits, and where a conventional
chemical or thermal step still does the job better.
What ozone does well
Ozone dissolves into water and reacts quickly with bacteria, viruses
and many oxidisable contaminants. In air and enclosed spaces it can
reach surfaces that are difficult to wipe. Because it decomposes back
to oxygen, there is no residual chemical to rinse away.
Where the engineering matters
Ozone is not stored; it is generated on site. The gas source, dew
point, cooling and contact tank determine how much ozone actually
reaches the target. A generator that performs on the test bench can
underperform if the feed gas is humid or the contact time is too short.
Ozone is a process, not a cartridge. The generator, gas preparation and contact stage have to be designed together.
For residual protection in a distribution network, a chemical step
may still be required. For shock disinfection, surface treatment and
process water, ozone is often the simpler route.
Aquaculture
28 October 2026
5 min read
Micro-nano bubbles in aquaculture: what dissolved oxygen really changes.
Traditional aeration produces large bubbles that rise quickly and
release most of their oxygen at the surface. Micro-nano bubbles are
much smaller, with a larger surface area and a longer residence time
in water.
Why the bubble size matters
Smaller bubbles create more gas-liquid contact area and stay in the
water column longer. That improves oxygen transfer efficiency and
helps maintain dissolved oxygen through the night and during high
stocking density.
Beyond oxygen
- Local oxidation can help break down some organic load
- Bubbles attach to suspended solids and support separation
- Improved dissolved oxygen supports aerobic treatment
- Better water conditions reduce stress on fish and shrimp
The right configuration depends on pond volume, oxygen demand,
power supply and whether the goal is emergency oxygen, daily
conditioning or wastewater treatment.
Specification
9 October 2026
5 min read
Specifying an ozone generator: gas source, cooling and control.
Two generators can look similar and perform very differently. The
difference is usually in the feed gas, the discharge chamber and how
the unit handles heat and moisture.
Gas source and dew point
Oxygen-source systems produce a higher ozone concentration than
air-source systems, but the oxygen supply and dryer have to be
specified. Moisture in the feed gas reduces output and stresses the
discharge chamber.
Cooling and chamber design
The honeycomb discharge chamber is designed to remove heat and keep
the gas path stable. Cooling method, gas pressure and enclosure
ventilation all affect continuous running.
Control and protection
- Automatic or programmable cycle control
- Multi-stage electrical protection
- Clear fault indication for service
- Materials matched to the installation environment
Service
21 September 2026
4 min read
Keeping an ozone system safe and serviceable.
Ozone is generated on site and used immediately. The safety approach
is therefore about containment, ventilation and maintenance access —
not about storing a chemical.
Practical rules
- Ventilate the generator room and monitor for leaks
- Keep the feed gas dry and the cooling path clear
- Inspect seals, tubing and electrical connections on schedule
- Isolate and purge before service
- Use suitable PPE when working near an operating system
A serviceable installation leaves room around the enclosure, labels
the isolation points and keeps the manual with the unit. That is as
important as the ozone output on the nameplate.